All templates
GlazingCommercial

Skylight Installation Inspection & Test Plan

ITP for skylight and roof glazing systems covering structural support, kerb construction, glazing installation, weatherproofing and fall protection compliance per AS 1288 and AS 4285.

12 checklist items
3 hold points
1 witness points
Use this template — it's free

Checklist Preview

Kerb & Structure

Requires sign-off
P/F
Structural opening per design drawings
P/F
Kerb height and construction per detail
P/F
Kerb waterproofed and flashed to roof membrane
Hold
P/F
Fall protection provisions for maintenance

Glazing Installation

Requires sign-off
P/F
Glass specification per AS 1288 (overhead glazing)
Hold
P/F
Frame fixed to kerb per manufacturer spec
P/F
Glazing seals and gaskets installed
P/F
Condensation gutter and drainage provision

Weathering & Completion

Requires sign-off
P/F
Perimeter flashing integrated with roof
P/F
Sealant application continuous
P/F
Water test satisfactory
Hold Witness
P/F
Safety screen or fall-through protection installed

Ready to use this template?

Sign up for free, import this ITP template into your project, and start inspecting. Your first project is always free.