All templates
PlumbingResidential

Hot Water System Installation Inspection & Test Plan

ITP for hot water system installation including storage or instantaneous units, tempering valve settings, relief valve piping and energy efficiency compliance per AS/NZS 3500.4.

13 checklist items
2 hold points
1 witness points
Use this template — it's free

Checklist Preview

Unit Installation

Requires sign-off
P/F
Unit positioned with required clearances
P/F
Seismic restraint installed if required
P/F
TPR valve discharge piped to safe location
Hold
P/F
Cold water isolation valve accessible
P/F
Expansion control valve installed

Tempering & Temperature Control

Requires sign-off
P/F
Thermostatic mixing valve installed
P/F
Outlet temperature ≤ 50°C at fixtures
Hold Witness
P/F
Storage temperature ≥ 60°C verified
#
Measured outlet temperature (°C)

Connections & Commissioning

P/F
Gas connection per AS 5601 (if applicable)
P/F
Electrical connection compliant
P/F
System flushed and commissioned
Manufacturer warranty registered

Ready to use this template?

Sign up for free, import this ITP template into your project, and start inspecting. Your first project is always free.