All templates
Structural SteelCommercial

Structural Steel Erection Inspection & Test Plan

ITP for on-site erection of structural steelwork covering crane operations, temporary bracing, alignment, plumb checks and connection completion per AS 4100.

13 checklist items
3 hold points
2 witness points
Use this template — it's free

Checklist Preview

Pre-Erection Checks

Requires sign-off
P/F
Erection sequence plan reviewed
P/F
Base plates and anchor bolts surveyed
Hold
P/F
Grout bed levels set to tolerance
P/F
Members identified and match delivery schedule

Erection Process

Requires sign-off
P/F
Crane lift plan approved
P/F
Temporary connections securing members
P/F
Column plumb within H/500 tolerance
Hold Witness
P/F
Beam levels within ±5mm tolerance
P/F
Temporary bracing installed per plan

Permanent Connections

Requires sign-off
P/F
Bolts installed and tensioned per specification
Hold
P/F
Site welding completed per WPS
Witness
P/F
Touch-up coating at connections complete
As-built survey completed