All templates
TilingResidential

Tiling Waterproofing Integration Inspection & Test Plan

Dedicated ITP for the coordination between waterproofing and tiling trades covering membrane cure times, bond-breaker avoidance, screed adhesion and puddle flange integration for wet area tiling.

12 checklist items
2 hold points
1 witness points
Use this template — it's free

Checklist Preview

Membrane Readiness

Requires sign-off
P/F
Membrane fully cured per manufacturer spec
Hold
P/F
Adhesion test on membrane surface satisfactory
P/F
No bond-breaking contaminants on membrane
P/F
Flood test certificate obtained
Hold

Screed over Membrane

Requires sign-off
P/F
Screed type compatible with membrane system
P/F
Screed graded to waste outlet
P/F
Screed thickness per specification
P/F
Puddle flange level with finished screed surface
Witness

Wet Area Tiling

Requires sign-off
P/F
Adhesive rated for wet area application
P/F
Hob and niche tiling integrated with membrane
P/F
Grout type suitable for wet area exposure
P/F
Silicone at all internal corners and junctions

Ready to use this template?

Sign up for free, import this ITP template into your project, and start inspecting. Your first project is always free.