WaterproofingCommercial
Podium Deck Waterproofing Inspection & Test Plan
ITP for podium deck and planter box waterproofing in multi-storey developments covering trafficable membrane systems, drainage design, expansion joints and long-term maintenance access.
12 checklist items
3 hold points
1 witness points
Checklist Preview
Substrate & Falls
Requires sign-offP/F
Structural deflection criteria metP/F
Falls to drainage points verified Hold
P/F
Structural cracks treated prior to membraneP/F
Substrate surface profile suitable for adhesionMembrane System
Requires sign-offP/F
Membrane system rated for trafficable applicationP/F
Expansion joints treated per detail HoldPhoto
P/F
Upstand heights per AS 4654.2P/F
Planter internal lining continuousTesting & Protection
Requires sign-offP/F
Flood test satisfactory (48-hour minimum) Hold Witness
P/F
Root barrier installed in planter areasP/F
Protection and drainage layer installedP/F
Long-term maintenance access provisions notedPrefer AI?
Generate a custom Waterproofing ITP in seconds
Describe your scope and our AI builds a complete ITP with hold points, witness points, and sign-off roles — tailored to your project.
Free AI ITP Generator →Ready to use this template?
Sign up, import this ITP template into your project, and start inspecting. 14 days free — no credit card required.